smartctl 6.1 2013-03-16 r3800 [i686-w64-mingw32-win7-sp1] (sf-6.1-2) Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: ExcelStor Technology J680 Serial Number: VN621EG2B8YEDB Firmware Version: V32OA60A User Capacity: 82'348'277'760 bytes [82.3 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA/ATAPI-6 T13/1410D revision 3a Local Time is: Mon Jan 11 00:58:55 2016 WEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Disabled APM feature is: Disabled Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, frozen [SEC2] === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 1828) seconds. Offline data collection capabilities: (0x1b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 31) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate PO-R-- 100 100 060 - 0 2 Throughput_Performance P-S--- 100 100 050 - 0 3 Spin_Up_Time POS--- 101 101 024 - 197 (Average 196) 4 Start_Stop_Count -O--C- 100 100 000 - 69 5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0 7 Seek_Error_Rate PO-R-- 100 100 067 - 0 8 Seek_Time_Performance P-S--- 100 100 020 - 0 9 Power_On_Hours -O--C- 100 100 000 - 46 10 Spin_Retry_Count PO--C- 100 100 060 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 69 192 Power-Off_Retract_Count -O--CK 100 100 050 - 70 193 Load_Cycle_Count -O--C- 100 100 050 - 70 194 Temperature_Celsius -O---- 141 141 000 - 39 (Min/Max 20/44) 196 Reallocated_Event_Count -O--CK 100 100 000 - 0 197 Current_Pending_Sector -O---K 100 100 000 - 0 198 Offline_Uncorrectable ---R-- 100 100 000 - 0 199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log SMART Extended Comprehensive Error Log Version: 1 (1 sectors) Device Error Count: 40 (device log contains only the most recent 4 errors) CR = Command Register FEATR = Features Register COUNT = Count (was: Sector Count) Register LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8 LH = LBA High (was: Cylinder High) Register ] LBA LM = LBA Mid (was: Cylinder Low) Register ] Register LL = LBA Low (was: Sector Number) Register ] DV = Device (was: Device/Head) Register DC = Device Control Register ER = Error register ST = Status register Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 40 [3] occurred at disk power-on lifetime: 1 hours (0 days + 1 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 59 00 01 00 00 00 00 00 64 e0 00 Error: UNC at LBA = 0x00000064 = 100 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 21 ac 44 00 01 00 00 64 00 00 64 e0 00 00:00:30.500 READ SECTOR(S) [OBS-5] 32 ac 44 00 01 ff ff 11 00 00 64 e0 00 00:00:30.500 WRITE LONG [OBS-4] ef ac 44 00 00 00 00 00 ff ff 11 e0 00 00:00:30.500 SET FEATURES [Length of VS data] [OBS-4] fb ac ac 00 01 00 00 00 ff ff 00 e0 00 00:00:30.500 [VENDOR SPECIFIC] fa 44 ac 00 01 00 00 00 ff ff 64 e0 00 00:00:30.500 [VENDOR SPECIFIC] Error 39 [2] occurred at disk power-on lifetime: 1 hours (0 days + 1 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 59 00 01 00 00 00 00 00 64 e0 00 Error: UNC at LBA = 0x00000064 = 100 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 21 ac 44 00 01 00 00 64 00 00 64 e0 00 00:00:30.300 READ SECTOR(S) [OBS-5] 32 ac 44 00 01 ff ff 11 00 00 64 e0 00 00:00:30.300 WRITE LONG [OBS-4] ef ac 44 00 00 00 00 00 ff ff 11 e0 00 00:00:30.300 SET FEATURES [Length of VS data] [OBS-4] fb ac ac 00 01 00 00 00 ff ff 00 e0 00 00:00:30.300 [VENDOR SPECIFIC] fa 44 ac 00 01 00 00 00 ff ff 64 e0 00 00:00:30.300 [VENDOR SPECIFIC] Error 38 [1] occurred at disk power-on lifetime: 1 hours (0 days + 1 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 59 00 01 00 00 00 00 00 64 e0 00 Error: UNC at LBA = 0x00000064 = 100 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 21 ac 44 00 01 00 00 64 00 00 64 e0 00 00:00:30.100 READ SECTOR(S) [OBS-5] 32 ac 44 00 01 ff ff 11 00 00 64 e0 00 00:00:30.100 WRITE LONG [OBS-4] ef ac 44 00 00 00 00 00 ff ff 11 e0 00 00:00:30.100 SET FEATURES [Length of VS data] [OBS-4] fb ac ac 00 01 00 00 00 ff ff 00 e0 00 00:00:30.100 [VENDOR SPECIFIC] fa 44 ac 00 01 00 00 00 ff ff 64 e0 00 00:00:30.100 [VENDOR SPECIFIC] Error 37 [0] occurred at disk power-on lifetime: 1 hours (0 days + 1 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 59 00 01 00 00 00 00 00 64 e0 00 Error: UNC at LBA = 0x00000064 = 100 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 21 ac 44 00 01 00 00 64 00 00 64 e0 00 00:00:29.900 READ SECTOR(S) [OBS-5] 32 ac 44 00 01 ff ff 11 00 00 64 e0 00 00:00:29.900 WRITE LONG [OBS-4] ef ac 44 00 00 00 00 00 ff ff 11 e0 00 00:00:29.900 SET FEATURES [Length of VS data] [OBS-4] fb ac ac 00 01 00 00 00 ff ff 00 e0 00 00:00:29.900 [VENDOR SPECIFIC] fa 44 ac 00 01 00 00 00 ff ff 64 e0 00 00:00:29.900 [VENDOR SPECIFIC] SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 45 - Selective Self-tests/Logging not supported SCT Commands not supported Device Statistics (GP Log 0x04) not supported SATA Phy Event Counters (GP Log 0x11) not supported