smartctl 6.1 2013-03-16 r3800 [i686-w64-mingw32-win7-sp1] (sf-6.1-2) Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Hitachi Travelstar 5K100 Device Model: Hitachi HTS541060G9AT00 Serial Number: MPB3PAXMG12YLG Firmware Version: MB3OA61A User Capacity: 60'011'642'880 bytes [60.0 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA/ATAPI-6 T13/1410D revision 3a Local Time is: Thu Apr 24 04:00:05 2014 WEDT SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM level is: 128 (quiet), recommended: 128 APM level is: 128 (minimum power consumption without standby) Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, frozen [SEC2] === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 645) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 42) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0 2 Throughput_Performance --S--- 106 106 000 - 4547 3 Spin_Up_Time POS--- 155 155 033 - 2 4 Start_Stop_Count -O--C- 100 100 000 - 430 5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0 7 Seek_Error_Rate -O-R-- 100 100 000 - 0 8 Seek_Time_Performance --S--- 120 120 000 - 40 9 Power_On_Hours -O--C- 100 100 000 - 293 10 Spin_Retry_Count -O--C- 100 100 000 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 415 191 G-Sense_Error_Rate -O-R-- 100 100 000 - 65536 192 Power-Off_Retract_Count -O--CK 100 100 000 - 50 193 Load_Cycle_Count -O--C- 100 100 000 - 9120 194 Temperature_Celsius -O---- 166 166 000 - 33 (Min/Max 14/49) 196 Reallocated_Event_Count -O--CK 100 100 000 - 0 197 Current_Pending_Sector -O---K 100 100 000 - 0 198 Offline_Uncorrectable ---R-- 100 100 000 - 0 199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: Input/output error Read GP Log Directory failed SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x06 SL R/O 1 SMART self-test log 0x80-0x9f SL R/W 16 Host vendor specific log SMART Extended Comprehensive Error Log (GP Log 0x03) not supported SMART Error Log Version: 1 No Errors Logged SMART Extended Self-test Log (GP Log 0x07) not supported SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 292 - Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum. SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Commands not supported Device Statistics (GP Log 0x04) not supported SATA Phy Event Counters (GP Log 0x11) not supported