smartctl 6.1 2013-03-16 r3800 [i686-w64-mingw32-win7-sp1] (sf-6.1-2) Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: IBM Deskstar 60GXP Device Model: IC35L040AVER07-0 Serial Number: SXPTXFA8646 Firmware Version: ER4OA44A User Capacity: 41'174'138'880 bytes [41.1 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA/ATAPI-5 T13/1321D revision 1 Local Time is: Thu Dec 10 12:51:51 2015 WEST ==> WARNING: IBM Deskstar 60GXP drives may need upgraded SMART firmware. Please see http://haque.net/dtla_update/ SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Disabled APM feature is: Disabled Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, frozen [SEC2] === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 1383) seconds. Offline data collection capabilities: (0x1b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 23) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate PO-R-- 100 100 060 - 0 2 Throughput_Performance P-S--- 100 100 050 - 0 3 Spin_Up_Time POS--- 103 103 024 - 213 (Average 214) 4 Start_Stop_Count -O--C- 100 100 000 - 2599 5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0 7 Seek_Error_Rate PO-R-- 100 100 067 - 0 8 Seek_Time_Performance P-S--- 100 100 020 - 0 9 Power_On_Hours -O--C- 098 098 000 - 15727 10 Spin_Retry_Count PO--C- 100 100 060 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 2380 192 Power-Off_Retract_Count -O--CK 098 098 050 - 2599 193 Load_Cycle_Count -O--C- 098 098 050 - 2599 194 Temperature_Celsius -O---- 137 137 000 - 40 (Min/Max 11/55) 196 Reallocated_Event_Count -O--CK 100 100 000 - 0 197 Current_Pending_Sector -O---K 100 100 000 - 0 198 Offline_Uncorrectable ---R-- 100 100 000 - 0 199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning Read SMART Log Directory failed: Input/output error ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: Input/output error Read GP Log Directory failed SMART Extended Comprehensive Error Log (GP Log 0x03) not supported SMART Error Log Version: 1 No Errors Logged SMART Extended Self-test Log (GP Log 0x07) not supported SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 15726 - Selective Self-tests/Logging not supported SCT Commands not supported Device Statistics (GP Log 0x04) not supported SATA Phy Event Counters (GP Log 0x11) not supported