smartctl 6.3 2014-07-26 r3976 [i686-w64-mingw32-win7-sp1] (sf-6.3-1) Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate Barracuda 7200.7 and 7200.7 Plus Device Model: ST380013AS Serial Number: 5MR415C5 Firmware Version: 8.12 User Capacity: 80'000'000'000 bytes [80.0 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA/ATAPI-6 T13/1410D revision 2 Local Time is: Thu Sep 10 03:47:04 2015 MS SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Disabled APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 430) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 47) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-- 060 050 006 - 186114713 3 Spin_Up_Time PO---- 098 098 000 - 0 4 Start_Stop_Count -O--CK 098 098 020 - 2532 5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0 7 Seek_Error_Rate POSR-- 087 060 030 - 634761396 9 Power_On_Hours -O--CK 085 085 000 - 13315 10 Spin_Retry_Count PO--C- 100 100 097 - 0 12 Power_Cycle_Count -O--CK 098 098 020 - 2533 194 Temperature_Celsius -O---K 045 049 000 - 45 (0 11 0 0 0) 195 Hardware_ECC_Recovered -O-RC- 060 050 000 - 186114713 197 Current_Pending_Sector -O--C- 100 100 000 - 0 198 Offline_Uncorrectable ----C- 100 100 000 - 0 199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0 200 Multi_Zone_Error_Rate ------ 100 253 000 - 0 202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 GPL,SL R/O 1 Summary SMART error log 0x02 GPL,SL R/O 5 Comprehensive SMART error log 0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log 0x06 GPL,SL R/O 1 SMART self-test log 0x07 GPL,SL R/O 1 Extended self-test log 0x09 GPL,SL R/W 1 Selective self-test log 0x20 GPL,SL R/O 1 Streaming performance log [OBS-8] 0x21 GPL,SL R/O 1 Write stream error log 0x22 GPL,SL R/O 1 Read stream error log 0x23 GPL,SL R/O 1 Delayed sector log [OBS-8] 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0 GPL,SL VS 1 Device vendor specific log 0xa1 GPL,SL VS 20 Device vendor specific log 0xa2 GPL,SL VS 101 Device vendor specific log 0xa8 GPL,SL VS 20 Device vendor specific log 0xa9 GPL,SL VS 1 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer 0xff GPL - 23552 Reserved SMART Extended Comprehensive Error Log Version: 1 (5 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 13314 - # 2 Short offline Completed without error 00% 1 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Commands not supported Device Statistics (GP Log 0x04) not supported SATA Phy Event Counters (GP Log 0x11) not supported