smartctl 6.1 2013-03-16 r3800 [i686-w64-mingw32-win7-sp1] (sf-6.1-2) Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Caviar Blue Serial ATA Device Model: WDC WD10EALS-00Z8A0 Serial Number: WD-WCATR4827048 LU WWN Device Id: 5 0014ee 25a9c9507 Firmware Version: 05.01D05 User Capacity: 1'000'204'886'016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS (minor revision not indicated) SATA Version is: SATA 2.6, 3.0 Gb/s Local Time is: Fri May 23 15:49:58 2014 WEDT SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Disabled APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, frozen [SEC2] === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (15900) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 184) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x3037) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0 3 Spin_Up_Time POS--K 173 171 021 - 4308 4 Start_Stop_Count -O--CK 100 100 000 - 511 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 093 093 000 - 5718 10 Spin_Retry_Count -O--CK 100 100 000 - 0 11 Calibration_Retry_Count -O--CK 100 100 000 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 502 192 Power-Off_Retract_Count -O--CK 200 200 000 - 34 193 Load_Cycle_Count -O--CK 200 200 000 - 476 194 Temperature_Celsius -O---K 107 099 000 - 40 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 200 200 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 6 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log 0xa8-0xb5 GPL,SL VS 1 Device vendor specific log 0xb6 GPL VS 1 Device vendor specific log 0xb7 GPL,SL VS 1 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xc1 GPL VS 24 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (6 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 5704 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 2 SCT Version (vendor specific): 258 (0x0102) SCT Support Level: 1 Device State: Active (0) Current Temperature: 40 Celsius Power Cycle Min/Max Temperature: 26/45 Celsius Lifetime Min/Max Temperature: 40/48 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -41/85 Celsius Temperature History Size (Index): 478 (466) Index Estimated Time Temperature Celsius 467 2014-05-23 07:52 41 ********************** ... ..(236 skipped). .. ********************** 226 2014-05-23 11:49 41 ********************** 227 2014-05-23 11:50 40 ********************* ... ..( 10 skipped). .. ********************* 238 2014-05-23 12:01 40 ********************* 239 2014-05-23 12:02 44 ************************* ... ..( 11 skipped). .. ************************* 251 2014-05-23 12:14 44 ************************* 252 2014-05-23 12:15 45 ************************** 253 2014-05-23 12:16 44 ************************* ... ..( 3 skipped). .. ************************* 257 2014-05-23 12:20 44 ************************* 258 2014-05-23 12:21 45 ************************** 259 2014-05-23 12:22 44 ************************* ... ..( 26 skipped). .. ************************* 286 2014-05-23 12:49 44 ************************* 287 2014-05-23 12:50 43 ************************ 288 2014-05-23 12:51 44 ************************* 289 2014-05-23 12:52 44 ************************* 290 2014-05-23 12:53 43 ************************ 291 2014-05-23 12:54 44 ************************* 292 2014-05-23 12:55 44 ************************* 293 2014-05-23 12:56 44 ************************* 294 2014-05-23 12:57 43 ************************ ... ..( 6 skipped). .. ************************ 301 2014-05-23 13:04 43 ************************ 302 2014-05-23 13:05 44 ************************* 303 2014-05-23 13:06 43 ************************ ... ..( 6 skipped). .. ************************ 310 2014-05-23 13:13 43 ************************ 311 2014-05-23 13:14 44 ************************* 312 2014-05-23 13:15 43 ************************ ... ..( 39 skipped). .. ************************ 352 2014-05-23 13:55 43 ************************ 353 2014-05-23 13:56 42 *********************** 354 2014-05-23 13:57 43 ************************ 355 2014-05-23 13:58 43 ************************ 356 2014-05-23 13:59 42 *********************** 357 2014-05-23 14:00 42 *********************** 358 2014-05-23 14:01 43 ************************ 359 2014-05-23 14:02 42 *********************** ... ..( 8 skipped). .. *********************** 368 2014-05-23 14:11 42 *********************** 369 2014-05-23 14:12 41 ********************** ... ..( 96 skipped). .. ********************** 466 2014-05-23 15:49 41 ********************** SCT Error Recovery Control command not supported Device Statistics (GP Log 0x04) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x000a 2 1 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x8000 4 46155 Vendor specific