smartctl 6.6 2017-11-05 r4594 [x86_64-w64-mingw32-win7-sp1] (sf-6.6-1) Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Scorpio Blue Serial ATA (AF) Device Model: WDC WD3200BPVT-24JJ5T0 Serial Number: WD-WX81E32SYV64 LU WWN Device Id: 5 0014ee 6ad702cc2 Firmware Version: 01.01A01 User Capacity: 320'072'933'376 bytes [320 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 5400 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS (minor revision not indicated) SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s) Local Time is: Tue Jun 18 14:36:22 2019 MS SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM level is: 128 (minimum power consumption without standby) Rd look-ahead is: Enabled Write cache is: Enabled DSN feature is: Unavailable ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 7080) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 73) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x7035) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0 3 Spin_Up_Time POS--K 143 137 021 - 1808 4 Start_Stop_Count -O--CK 096 096 000 - 4015 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 100 253 000 - 0 9 Power_On_Hours -O--CK 091 091 000 - 7081 10 Spin_Retry_Count -O--CK 100 100 000 - 0 11 Calibration_Retry_Count -O--CK 100 100 000 - 0 12 Power_Cycle_Count -O--CK 097 097 000 - 3803 192 Power-Off_Retract_Count -O--CK 200 200 000 - 127 193 Load_Cycle_Count -O--CK 153 153 000 - 143853 194 Temperature_Celsius -O---K 110 070 000 - 33 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 100 253 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 6 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log 0xa8-0xb7 GPL,SL VS 1 Device vendor specific log 0xbd GPL,SL VS 1 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xc1 GPL VS 93 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (6 sectors) Device Error Count: 3 CR = Command Register FEATR = Features Register COUNT = Count (was: Sector Count) Register LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8 LH = LBA High (was: Cylinder High) Register ] LBA LM = LBA Mid (was: Cylinder Low) Register ] Register LL = LBA Low (was: Sector Number) Register ] DV = Device (was: Device/Head) Register DC = Device Control Register ER = Error register ST = Status register Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 3 [2] occurred at disk power-on lifetime: 82 hours (3 days + 10 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 80 00 00 03 30 c5 e8 e0 00 Error: UNC 128 sectors at LBA = 0x0330c5e8 = 53528040 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 25 00 00 00 80 00 00 03 30 c5 b0 e0 00 00:00:11.373 READ DMA EXT 25 00 00 00 80 00 00 03 30 c5 b0 e0 00 00:00:08.610 READ DMA EXT 25 00 00 00 80 00 00 03 30 c5 b0 e0 00 00:00:05.866 READ DMA EXT 25 00 00 00 80 00 00 03 30 c5 30 e0 00 00:00:05.864 READ DMA EXT 25 00 00 00 80 00 00 03 30 c4 b0 e0 00 00:00:05.863 READ DMA EXT Error 2 [1] occurred at disk power-on lifetime: 82 hours (3 days + 10 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 80 00 00 03 30 c5 e8 e0 00 Error: UNC 128 sectors at LBA = 0x0330c5e8 = 53528040 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 25 00 00 00 80 00 00 03 30 c5 b0 e0 00 00:00:08.610 READ DMA EXT 25 00 00 00 80 00 00 03 30 c5 b0 e0 00 00:00:05.866 READ DMA EXT 25 00 00 00 80 00 00 03 30 c5 30 e0 00 00:00:05.864 READ DMA EXT 25 00 00 00 80 00 00 03 30 c4 b0 e0 00 00:00:05.863 READ DMA EXT 25 00 00 00 80 00 00 03 30 c4 30 e0 00 00:00:05.862 READ DMA EXT Error 1 [0] occurred at disk power-on lifetime: 82 hours (3 days + 10 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 40 -- 51 00 80 00 00 03 30 c5 e8 e0 00 Error: UNC 128 sectors at LBA = 0x0330c5e8 = 53528040 Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- 25 00 00 00 80 00 00 03 30 c5 b0 e0 00 00:00:05.866 READ DMA EXT 25 00 00 00 80 00 00 03 30 c5 30 e0 00 00:00:05.864 READ DMA EXT 25 00 00 00 80 00 00 03 30 c4 b0 e0 00 00:00:05.863 READ DMA EXT 25 00 00 00 80 00 00 03 30 c4 30 e0 00 00:00:05.862 READ DMA EXT 25 00 00 00 80 00 00 03 30 c3 b0 e0 00 00:00:05.862 READ DMA EXT SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 7079 - # 2 Short offline Aborted by host 80% 4082 - # 3 Vendor (0x50) Completed without error 00% 3284 - # 4 Short offline Completed without error 00% 3284 - # 5 Vendor (0x50) Aborted by host 70% 1054 - # 6 Short offline Completed without error 00% 1054 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 258 (0x0102) SCT Support Level: 1 Device State: Active (0) Current Temperature: 34 Celsius Power Cycle Min/Max Temperature: 26/35 Celsius Lifetime Min/Max Temperature: 0/73 Celsius Under/Over Temperature Limit Count: 0/0 Vendor specific: 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -41/85 Celsius Temperature History Size (Index): 128 (98) Index Estimated Time Temperature Celsius 99 2019-06-18 12:29 33 ************** ... ..( 4 skipped). .. ************** 104 2019-06-18 12:34 33 ************** 105 2019-06-18 12:35 32 ************* 106 2019-06-18 12:36 32 ************* 107 2019-06-18 12:37 31 ************ ... ..( 8 skipped). .. ************ 116 2019-06-18 12:46 31 ************ 117 2019-06-18 12:47 32 ************* ... ..( 6 skipped). .. ************* 124 2019-06-18 12:54 32 ************* 125 2019-06-18 12:55 31 ************ ... ..( 19 skipped). .. ************ 17 2019-06-18 13:15 31 ************ 18 2019-06-18 13:16 32 ************* ... ..( 2 skipped). .. ************* 21 2019-06-18 13:19 32 ************* 22 2019-06-18 13:20 33 ************** ... ..( 7 skipped). .. ************** 30 2019-06-18 13:28 33 ************** 31 2019-06-18 13:29 34 *************** ... ..( 6 skipped). .. *************** 38 2019-06-18 13:36 34 *************** 39 2019-06-18 13:37 35 **************** ... ..( 56 skipped). .. **************** 96 2019-06-18 14:34 35 **************** 97 2019-06-18 14:35 34 *************** 98 2019-06-18 14:36 34 *************** SCT Error Recovery Control command not supported Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 1 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x8000 4 13554 Vendor specific